Ouellet Canada - Products Catalog - page 34

Products Catalog 2015-2016 •
32
OTP-MZ
Option
Models
Product #
Description
OTP-WB3
Adjustable wall bracket for outdoor unit
Product #
1
2x
OTP-B12000D-I
1x
OTP-MZ24000D-E
Technical Performance
SEER
-
15
HSPF
-
8.2
Energy Star
-
No
Indoor Unit
Cooling capacity
W (BTU/hr)
3517 (12000)
Heating capacity
W (BTU/hr)
3810 (13000)
Dehumidifying volume
pt/hr (l/hr)
2.96 (2.8)
Air flow volume
T / H / M / L
2
cfm
335 / 277 / 253 / 218
Sound level
T / H / M / L
2
dB (A)
44 / 39 / 36 / 33
Fan motor power output
W
20
Fan motor RLA
A
0.2
Deflector stepper motor power output
W
2
Weight
lb (kg)
22 (10)
Outdoor Unit
Cooling capacity
Nominal
W (BTU/hr)
7620 (26000)
Min. – max.
W (BTU/hr)
2198 - 9671 (7500 - 33000)
Heating capacity
Nominal
W (BTU/hr)
8499 (29000)
Min. – max.
W (BTU/hr)
2198 - 10257 (7500 - 35000)
Used cooling power input
Nominal
W
3050
Min. – max.
W
650 – 4500
Used heating power input
Nominal
W
2800
Min. – max.
W
980 – 3950
Air flow volume
H / M / L
cfm
1942 / 1707 / 1413
Sound level
dB (A)
58
Compressor power output
W
2200
Compressor LRA
A
45
Compressor RLA
A
9.4
Fan motor power output
W
60
Fan motor RLA
A
0.59
Refrigerant volume (R410A)
oz (g)
77.6 (2200)
Weight
lb (kg)
134 (61)
Connection Piping
Additional refrigerant charge
oz/ft. (g/m)
0.2 (18.6)
Liquid pipe outer diameter
in.
1/4
Gas pipe outer diameter
in.
3/8
Maximum height difference
ft. (m)
33 (10)
Maximum total length
ft. (m)
230 (70)
Drain pipe inner diameter
in.
5/8
1
2 indoor units and 1 outdoor unit. Note that each unit is individually wrapped.
2
Cross-Flow Fan Speeds: (T) Turbo / (H) High / (M) Medium / (L) Low.
1...,24,25,26,27,28,29,30,31,32,33 35,36,37,38,39,40,41,42,43,44,...128