Ouellet Canada - Products Catalog - page 40

Products Catalog 2015-2016 •
38
OWC-M
Heating Cable for Concrete on Mat
OWC-R
Heating Cable for Concrete in Reel
Cold lead length
• 8’2’’(2.5 m) cold lead included.
Control
• Two types of control method possible (see instruction manual
for details):
- Surface heating control with electronic thermostat in floor mode (F)
and temperature sensor.
- Ambient heating control with electronic thermostat in ambient
mode with floor limit (A or AF) and temperature sensor.
Note: A ground fault circuit interrupter (GFCI) must be used with this heating
device unless exempted by the applicable national and/or local electrical
code for the area of installation.
• See control options on pages 112 and 113.
Included materials
• 15' (4.6 m) temperature sensor.
• Electrical fault indicator (OTM-CC).
• Measurements table label (to be placed in electrical panel).
Installation
Never cut or shorten the heating cable.
• For indoor applications only, residential or commercial.
• Installs under a 4" to 6" (10 cm to 15 cm) concrete slab
or under a 1.5’’to 4’’concrete topping (4 cm to 10 cm).
Note: It’s highly recommended to insulate the concrete slab in order to avoid
heat loss from below (see instruction manual for all installation details).
• Compatible with most floor coverings
(check with the dealer or manufacturer).
Warranty
• 20-year warranty on the heating cable.
Application
• Basement, garage, bathroom, kitchen, family room, workshop, pool,
shower, entrance way, hospital, hotel, factory, business, restaurant,
sunroom, greenhouse.
Features
Training available online
Voltage
• 240/208V, 347V, 1-phase.
Construction
• Twin conductor heating cable attached to a plastic mat with negligible
magnetic field.
Watt density
• 11W/sq. ft. (120W/sq. m), factory installed on mat at 6’’(15 cm) spacing.
Dimension
• 24’’(0.6 m) wide mat available in several lengths.
Included materials
• Plastic floor fasteners (OW-CLP).
Installation
• Installation with or without metallic structure for reinforced concrete.
OWC-M Features
Voltage
• 240/208V, 1-phase.
Construction
• Twin conductor heating cable with negligible magnetic field.
Watt density
• 11W/sq. ft. (120W/sq. m), recommended installation – 6’’(15 cm) spacing.
Included materials
• Plastic tie-wraps (OW-TYW).
Installation
• Requires a metallic structure or wire mesh for reinforced concrete
with spacing of 6'' (15 cm) for the installation.
OWC-R Features
OWC-M:
on rigid insulation, under
concrete slab min. 4" (10 cm)
OWC-M:
under concrete topping
min. 1.5" (4 cm)
OWC-R:
on metal structure
24’’
0.6 m
Length (x)
OWC-M
Outer Sheath (PVC)
Metal Sheath (Copper and Steel)
Primary Insulation (Fluoropolymer)
Resistance Wires
1/4
"
6.5 mm
1...,30,31,32,33,34,35,36,37,38,39 41,42,43,44,45,46,47,48,49,50,...128